return to shopA GMB100 that will not start after repeated choke-assisted pulls may be flooded with excess fuel. Stop adding choke. The manual's clearing sequence has two separate phases: ignition OFF while clearing, then ignition enabled for a normal restart.
Is flooding a reasonable explanation?
Repeated starting attempts with the choke engaged make flooding worth considering. A gasoline smell may also be present, but smell alone cannot distinguish a flooded engine from a leak. Look for external wetness first; do not crank an engine with leaking fuel on or around it.
If the engine has not been prepared correctly, check its oil level, fuel supply, and control positions before assuming excess fuel is the problem. An engine that does not turn normally, or a starter cord that suddenly will not pull, needs diagnosis rather than harder pulling.
Keep clearing and restarting separate

- Prepare outdoors. Park on firm, level ground, clear people from the bike's path, and set the engine kill switch to OFF. Keep it OFF throughout the clearing stage.
- Set the choke to RUN. The clearing procedure does not use more choke.
- Clear with ignition disabled. Following section 6.2, hold the throttle open and pull the starter firmly several times. The manual describes a short clearing sequence of approximately 30 seconds. Stop if the starter does not move normally.
- Release the throttle fully. Confirm it has returned to its closed position before enabling ignition.
- Restart normally. Set the engine switch to its RUN/ON position and start with the choke still at RUN. Keep the throttle closed for the starting attempt.
The open-throttle step belongs only to the ignition-OFF clearing phase. Do not carry it into the restart: the bike could move if the engine starts with the throttle open.
What if it still will not start?
Do not repeat an endless cycle of choke, pulls, and clearing. Recheck that the fuel is correct and fresh, the oil level is correct, and the controls are in their intended positions. Fuel contamination, a blocked tank vent, or another fault may need a different remedy.
If the engine starts but only runs with choke, runs poorly, or repeatedly floods, arrange a fuel-system inspection. This procedure clears excess fuel; it does not correct a carburetor fault that keeps supplying too much.
Starting after a failed attempt
Should I use choke again after clearing a flooded engine?
The GMB100 clearing procedure calls for the restart with choke at RUN. Adding choke again can repeat the excess-fuel condition you were trying to clear.
Follow the symptom
For ordinary operation, use the GMB100 starting sequence. See manual section 6.2 and contact FRP support before ordering replacement parts for an unresolved GMB100 no-start problem.